Ticket #3616 (closed defect: fixed)

Opened 12 months ago

Last modified 11 months ago

Measure locks up if you click between microphone and sensor quickly

Reported by: carrott Owned by: walter
Priority: Unspecified by Maintainer Milestone: Unspecified by Release Team
Component: Measure Version: Unspecified
Severity: Unspecified Keywords:
Cc: Distribution/OS: Unspecified
Bug Status: Unconfirmed

Description (last modified by carrott) (diff)

On 12.1.0 build 9 and 10 on XO-1.75 and XO-1.5 with Measure 36

Start Measure
Click sensor (Ohm over a squiggle)
Quickly click the Micropohone
Repeat until measure locks up

This happens quite easily on XO-1.75, today it locked after only two clicks. It also happens on XO-1.5 but seems to take longer.

See attached for GDB backtrace and logs.

Attachments

measure-kiwi-gdb.txt.bz2 Download (11.8 KB) - added by carrott 12 months ago.
gdb backtrace after lock
org.laptop.MeasureActivity-1-kiwi.log.bz2 Download (4.8 KB) - added by carrott 12 months ago.
log of locked measure session

Change History

Changed 12 months ago by carrott

gdb backtrace after lock

Changed 12 months ago by carrott

log of locked measure session

Changed 12 months ago by carrott

  • description modified (diff)

Changed 12 months ago by walter

Changed 12 months ago by walter

forgot to mention: tested on XO1.75

Changed 11 months ago by walter

  • status changed from new to closed
  • resolution set to fixed
Note: See TracTickets for help on using tickets.